Trial Results
Independent lab testing and producer trials across ready-mix and precast, North America and Europe. The same data we share with commercial customers — now available for review upfront.
Tested by SGS TEC, Ideal Laboratory, and KCT Laboratory.
Fly Ash Blend Performance
Trident's effect across three cement-to-fly-ash ratios. Dosage held constant at 32.4 oz/m³ across all dosed mixes.
| Mix (Trident / Cement / Fly Ash, kg/m³) | 3-day PSI | 7-day PSI | 28-day PSI |
|---|---|---|---|
| Control — 0 / 400 / 200 | 2,973 | 3,873 | 5,083 |
| Trident — 32.4 / 400 / 200 | 3,915 | 5,148 | 6,605 |
| Control — 0 / 435 / 165 | 3,364 | 4,417 | 5,656 |
| Trident — 32.4 / 435 / 165 | 4,466 | 5,728 | 7,236 |
| Control — 0 / 470 / 130 | 4,128 | 5,210 | 6,534 |
| Trident — 32.4 / 470 / 130 | 5,076 | 6,718 | 8,361 |
+1,827 PSI
Best 28-day gain vs. control
Highest cement / lowest fly-ash blend, with dosage held at 32.4 oz/m³.
8,361 PSI
Peak 28-day strength
3 of 3
Blend ratios improved with Trident
50/50 OPC/GGBS Blend
Trident performance in a 50% slag-replacement mix at four dosage levels, tested at 1, 7, and 28 days.
| Mix | 1-day PSI | 7-day PSI | 28-day PSI |
|---|---|---|---|
| Control | 1,813 | 3,698 | 5,365 |
| F01-600g | 2,683 | 4,727 | 6,381 |
| F01-800g | 2,900 | 4,988 | 6,642 |
| F01-1000g | 3,088 | 5,277 | 6,989 |
| F01-1200g | 3,194 | 5,495 | 7,569 |
+1,381 PSI
Best 1-day gain for early-strength work
+2,204 PSI
Best 28-day gain vs. control
F01-1200g produced the strongest long-term improvement in the 50% slag mix.
7,569 PSI
Peak 28-day strength
European Ready-Mix R&D Validation
Multiple mix designs trialed by a European ready-mix R&D partner. PSI results at 1, 7, and 28 days.
| Mix | 1-day PSI | 7-day PSI | 28-day PSI |
|---|---|---|---|
| Control | 2,378 | 5,133 | 6,728 |
| F01-600g | 2,712 | 6,206 | 7,903 |
| F01-800g | 2,842 | 6,351 | 7,641 |
| F01-1000g | 2,969 | 6,075 | 7,379 |
+1,073–1,218 PSI
7-day gains at 600g and 800g
+1,175 PSI
Best 28-day gain vs. control
F01-600g reached 7,903 PSI while maintaining the trial's fresh-concrete properties.
No impact
Slump and air content maintained
Fly Ash Substitution Trial
A North American ready-mix producer trialed Trident alongside a 5% reduction in total cement and fly ash content, using Type F fly ash — the test of whether Trident could compensate for reduced cementitious content while still delivering strength gains.
| Mix | 7-day PSI | 28-day PSI | Cementitious |
|---|---|---|---|
| Control DCA 6 | 4,130 | 5,280 | Baseline |
| Trident DCA 6 @ 4.78 oz/cwt | 4,550 | 6,260 | −5% |
+420 PSI
7-day strength gain vs. control
+980 PSI
28-day strength gain vs. control
Strength increased even with less total cement and fly ash in the mix.
−5%
Total cementitious reduction
Strength gains while reducing total cementitious content — cost and carbon savings without compromising structural performance.
8-Hour Strength Development
A North American precast producer tested Trident against their control on Mix 201. The question: could Trident shorten their stripping time and enable more mold turns per day?
| Age | Control PSI | Trident PSI | Δ |
|---|---|---|---|
| 8 hours | 1,077 | 2,786 | +1,709 |
| 10 hours | 1,693 | 3,510 | +1,817 |
| 12 hours | 2,245 | 4,142 | +1,897 |
| 24 hours | 3,728 | 5,563 | +1,835 |
| 7 days | 6,284 | 8,120 | +1,836 |
| 14 days | 7,192 | 9,041 | +1,849 |
| 28 days | 7,843 | 9,798 | +1,955 |
159% gain
8-hour strength improvement
Trident pushed 8-hour PSI from 1,077 to 2,786, opening the path to faster stripping.
+1,709 PSI
8-hour gain vs. control
3x mold turns
Potential daily precast production capacity
HB Mix — 12-Hour Spec Compliance
Customer specification required a minimum 3,500 PSI at 24 hours. Trident was tested at three dosages (24 oz, 30 oz, 36 oz) to see if the spec could be met earlier.
| Mix | 12-hr PSI | 14-hr PSI | 7-day PSI | 28-day PSI |
|---|---|---|---|---|
| HB#1 — Control | 1,942 | 2,364 | 6,530 | 8,421 |
| HB#2 — 24 oz | 3,521 | 3,842 | 8,117 | 10,290 |
| HB#3 — 30 oz | 3,800 | 4,110 | 8,362 | 10,545 |
| HB#4 — 36 oz | 3,707 | 4,044 | 8,601 | 10,980 |
3,800 PSI
Best 12-hour result (HB#3, 30 oz)
12 hours early
All Trident batches cleared the 24-hour spec at 12 hours
Every Trident dosage exceeded the customer's 3,500 PSI requirement half a day ahead of schedule.
38% above spec
Best 14-hour result: 4,110 PSI
See what Trident does in your mix.