Pipedream Industries
Validation

Trial Results

Independent lab testing and producer trials across ready-mix and precast, North America and Europe. The same data we share with commercial customers — now available for review upfront.

Tested by SGS TEC, Ideal Laboratory, and KCT Laboratory.

01Independent Lab

Fly Ash Blend Performance

Trident's effect across three cement-to-fly-ash ratios. Dosage held constant at 32.4 oz/m³ across all dosed mixes.

Mix (Trident / Cement / Fly Ash, kg/m³)3-day PSI7-day PSI28-day PSI
Control — 0 / 400 / 2002,9733,8735,083
Trident — 32.4 / 400 / 2003,9155,1486,605
Control — 0 / 435 / 1653,3644,4175,656
Trident — 32.4 / 435 / 1654,4665,7287,236
Control — 0 / 470 / 1304,1285,2106,534
Trident — 32.4 / 470 / 1305,0766,7188,361
Dosage reference: 800 g = 3.8 oz/cwt · 1,000 g = 4.8 oz/cwt · 1,200 g = 5.8 oz/cwt.

+1,827 PSI

Best 28-day gain vs. control

Highest cement / lowest fly-ash blend, with dosage held at 32.4 oz/m³.

8,361 PSI

Peak 28-day strength

3 of 3

Blend ratios improved with Trident

02Independent Lab

50/50 OPC/GGBS Blend

Trident performance in a 50% slag-replacement mix at four dosage levels, tested at 1, 7, and 28 days.

Mix1-day PSI7-day PSI28-day PSI
Control1,8133,6985,365
F01-600g2,6834,7276,381
F01-800g2,9004,9886,642
F01-1000g3,0885,2776,989
F01-1200g3,1945,4957,569

+1,381 PSI

Best 1-day gain for early-strength work

+2,204 PSI

Best 28-day gain vs. control

F01-1200g produced the strongest long-term improvement in the 50% slag mix.

7,569 PSI

Peak 28-day strength

03European Ready-Mix

European Ready-Mix R&D Validation

Multiple mix designs trialed by a European ready-mix R&D partner. PSI results at 1, 7, and 28 days.

Mix1-day PSI7-day PSI28-day PSI
Control2,3785,1336,728
F01-600g2,7126,2067,903
F01-800g2,8426,3517,641
F01-1000g2,9696,0757,379

+1,073–1,218 PSI

7-day gains at 600g and 800g

+1,175 PSI

Best 28-day gain vs. control

F01-600g reached 7,903 PSI while maintaining the trial's fresh-concrete properties.

No impact

Slump and air content maintained

04North American Ready-Mix

Fly Ash Substitution Trial

A North American ready-mix producer trialed Trident alongside a 5% reduction in total cement and fly ash content, using Type F fly ash — the test of whether Trident could compensate for reduced cementitious content while still delivering strength gains.

Mix7-day PSI28-day PSICementitious
Control DCA 64,1305,280Baseline
Trident DCA 6 @ 4.78 oz/cwt4,5506,260−5%

+420 PSI

7-day strength gain vs. control

+980 PSI

28-day strength gain vs. control

Strength increased even with less total cement and fly ash in the mix.

−5%

Total cementitious reduction

Strength gains while reducing total cementitious content — cost and carbon savings without compromising structural performance.

05Precast Case Study

8-Hour Strength Development

A North American precast producer tested Trident against their control on Mix 201. The question: could Trident shorten their stripping time and enable more mold turns per day?

AgeControl PSITrident PSIΔ
8 hours1,0772,786+1,709
10 hours1,6933,510+1,817
12 hours2,2454,142+1,897
24 hours3,7285,563+1,835
7 days6,2848,120+1,836
14 days7,1929,041+1,849
28 days7,8439,798+1,955

159% gain

8-hour strength improvement

Trident pushed 8-hour PSI from 1,077 to 2,786, opening the path to faster stripping.

+1,709 PSI

8-hour gain vs. control

3x mold turns

Potential daily precast production capacity

06Precast Case Study

HB Mix — 12-Hour Spec Compliance

Customer specification required a minimum 3,500 PSI at 24 hours. Trident was tested at three dosages (24 oz, 30 oz, 36 oz) to see if the spec could be met earlier.

Mix12-hr PSI14-hr PSI7-day PSI28-day PSI
HB#1 — Control1,9422,3646,5308,421
HB#2 — 24 oz3,5213,8428,11710,290
HB#3 — 30 oz3,8004,1108,36210,545
HB#4 — 36 oz3,7074,0448,60110,980

3,800 PSI

Best 12-hour result (HB#3, 30 oz)

12 hours early

All Trident batches cleared the 24-hour spec at 12 hours

Every Trident dosage exceeded the customer's 3,500 PSI requirement half a day ahead of schedule.

38% above spec

Best 14-hour result: 4,110 PSI

See what Trident does in your mix.

Run a trial at your plant, with your materials, on your terms.